WTC POINTS TABLE UPDATE AFTER NZ VS WI TEST INDIA

Several grounding points for communication tower feeder lines

Several grounding points for communication tower feeder lines

The fundamental objective of this document is to provide guidelines and practices for Ericsson site equipment grounding, with recommended methods that are essential to protect personnel, minimize component failure, and optimize performance by reducing electrical noise. #2 AWG minimum bare tinned solid copper ground wire may be used to bond air terminals to the tower. Because bonding and grounding systems within a building are intended to have one electrical potential, coordination between electrical and telecommunications bonding and grounding systems is essential during design and installation. It can enter via the feeder screens that are grounded at the top of the tower, via surge protective devices within or external to tower mounted electronics, via side flashing to exposed connection points and other electrical mechanisms.

Read More
How to test the wavelength of an optical module

How to test the wavelength of an optical module

Therefore, we need to use a wavelength meter or wavelength sensor to measure the wavelength of the optical module and compare it with the specified wavelength range. Accurately testing an optical transceiver means proving two things: that the module is emitting the right power at the right wavelength, and that the link it's attached to delivers that signal without unexpected loss or reflections. An optical spectrum analyzer (OSA) quantifies and displays the power of an optical light source over a given wavelength range. Think of it as a "microscope for light," revealing details invisible to the naked eye. Digital Diagnostic Monitoring is a technology that enables real-time monitoring of various parameters in optical modules.

Read More
Splier Loss and Splitting Ratio Test

Splier Loss and Splitting Ratio Test

Testing a splitter or other passive fiber optic devices like switches is little different from testing a patchcord or cable plant using the two industry standard tests, OFSTP-14 for double-ended loss (connectors on both ends) or FOTP-171 for single-ended testing. Optical splitters are usually used in passive optical networks (PONs) to distribute fiber to individual homes or businesses. However, like any other network component, optical splitters can experience loss, which impacts the overall performance of the network.

Read More
Fireproof cable tray test

Fireproof cable tray test

To test this, the German standard DIN 4102-12 is used to test complete systems of wire ropes, accessories and cables. The wire ropes and cables are placed in an oven and heated for 90 minutes until the temperature reaches 1 000 °C. This includes checking their flammability, smoke production, toxic gas emissions, and ability to block heat and fire. Through these tests the aim was to learn more about thermal conductivity properties in fire conditions and what effects it would have on the tray itself and how long the installed cable. FireMaster® products insulate cable trays carrying instrument control cables to ensure that the cables can operate long enough to allow process shut down during fires.

Read More

Get In Touch

Connect With Us

📱

Spain Office (HQ)

+34 936 214 587

🇪🇺

EU Technical Center

+49 89 452 38 217

📍

Headquarters (Spain)

Calle de la Tecnología 47, 08840 Viladecans, Barcelona, Spain