MOBILE COLD ROOMS FOR SALE IN SOUTH AFRICA COLD

Cold aisle wall-mounted type for broadcast transmission equipment rooms

Cold aisle wall-mounted type for broadcast transmission equipment rooms

Cold Aisle Containment or CAC is a proven, relatively easy to deploy solution for effectively managing airflow within a data centre. A CAC system surrounds the cold aisle and it keeps cold supply air separate from hot server exhaust air. Ardmac have developed a range of Ground Supported (GS) and Ceiling Supported (CS) assemblies catering to an array of different modular clean rooms and off-site construction industry requirements including data centre design and data centre construction. An enormous amount of energy is used every day to maintain an acceptable intake temperature to the IT equipment. This buying guide will help you understand the features of an aisle containment system, learn the important questions to ask before selecting a solution and compare different types of aisle containment kits.

Read More
Fiber optic cold connectors are prone to breakage

Fiber optic cold connectors are prone to breakage

Accumulation of ice and snow on aerial fiber optic cables can add weight and cause sagging or tension, potentially leading to physical damage or breakage. These cables, composed of thin strands of glass or plastic, transmit data as light signals, ensuring rapid and efficient communication. There are three common types of fiber connectors: SC, ST (bayonet-twist) and LC (push-pull locking). The LC connector is most commonly chosen, because it is much smaller than the other two, and also provides a secure clip connection. The fiber connection is UV resistant, salt spray resistant and sealed to IP66, IP68 and IP69K, while still providing an industry-standard LC interface as specified by IEC 61754-20. Fiber optic cabling problems with extreme cold happen when water finds its way into the ducts housing the cables.

Read More
Dimensions of the cold aisle for oil pipeline monitoring room

Dimensions of the cold aisle for oil pipeline monitoring room

According to the ANSI/TIA/EIA-942-A standard, the recommended width for a cold aisle is 1,2 meters, which typically corresponds to the size of two double floor tiles. Cold air is supplied via perforated tiles at the front of the cabinets, which is distributed to cabinet by fans. Efficient airflow management in data centers relies heavily on proper Hot Aisle and Cold Aisle configurations. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. What is Cooling Optimization? Why is Cooling Optimization Important? "You can't purchase efficiency.

Read More
PC cold joint

PC cold joint

A cold solder joint forms when solder does not melt or wet the pad and component lead completely. Instead of creating a unified bond, the solder cools prematurely or never flows correctly, resulting in a dull, grainy, or uneven connection. They often look harmless, but can cause intermittent failures, unexpected resistance spikes, and field returns long after a product has passed initial testing. While these joints may look acceptable at first glance, they can become problematic over time, especially when exposed to vibration, thermal. This is the most common type of defect especially found under POP packages, where two or more Chip Scale Packages (CSP) or Ball Grid Array (BGA) components are placed one on top of the other and reflow soldered.

Read More

Get In Touch

Connect With Us

📱

Spain Office (HQ)

+34 936 214 587

🇪🇺

EU Technical Center

+49 89 452 38 217

📍

Headquarters (Spain)

Calle de la Tecnología 47, 08840 Viladecans, Barcelona, Spain