Several grounding points for communication tower feeder lines

Several grounding points for communication tower feeder lines

The fundamental objective of this document is to provide guidelines and practices for Ericsson site equipment grounding, with recommended methods that are essential to protect personnel, minimize component failure, and optimize performance by reducing electrical noise. #2 AWG minimum bare tinned solid copper ground wire may be used to bond air terminals to the tower. Because bonding and grounding systems within a building are intended to have one electrical potential, coordination between electrical and telecommunications bonding and grounding systems is essential during design and installation. It can enter via the feeder screens that are grounded at the top of the tower, via surge protective devices within or external to tower mounted electronics, via side flashing to exposed connection points and other electrical mechanisms.

Read More
Two busbar connectors put together

Two busbar connectors put together

This method uses rivets to join busbars by creating holes in the bars and securing them together. This process, called "jointing," may be needed to create a longer busbar from shorter, more manageable pieces; or to create a T-shaped tap-off connection from the main busbar. When bolting bars together is not an option or not preferred (for example, when combining busbars in a corner), flexibar can be used. Bus Couplers are switching devices, which are often circuit breakers, that are utilized to connect two (or) more busbars that are located within a substation. Is it correct to put two busbar of same phase without spacing? I know that when we connect two busbars it must be connected with appropriate number of bolts (depending on busbar size) so I just wondering is this correct or there should be some space between them? Pretty much he who designs it picks.

Read More
The impact of connecting pigtails on connectors

The impact of connecting pigtails on connectors

A: Pigtail connectors can flexibly connect multiple wires and protect connection points, such as reducing cable tension in electrical wiring, and comply with safety standards like UL/CSA. It serves as a bridge, allowing technicians to repair specific connection points without disturbing the rest of the system. Keep reading to learn how they factor into reliability and why they are a nonnegotiable component in modern.

Read More
Fiber optic cold connectors are prone to breakage

Fiber optic cold connectors are prone to breakage

Accumulation of ice and snow on aerial fiber optic cables can add weight and cause sagging or tension, potentially leading to physical damage or breakage. These cables, composed of thin strands of glass or plastic, transmit data as light signals, ensuring rapid and efficient communication. There are three common types of fiber connectors: SC, ST (bayonet-twist) and LC (push-pull locking). The LC connector is most commonly chosen, because it is much smaller than the other two, and also provides a secure clip connection. The fiber connection is UV resistant, salt spray resistant and sealed to IP66, IP68 and IP69K, while still providing an industry-standard LC interface as specified by IEC 61754-20. Fiber optic cabling problems with extreme cold happen when water finds its way into the ducts housing the cables.

Read More
What materials are fiber optic pigtail connectors made of

What materials are fiber optic pigtail connectors made of

5/125 micron or 50/125-micron bulk multimode fiber cables that are terminated at one end with multimode fiber optic connectors. The connector end is polished and tested under factory conditions, ensuring low insertion loss and high return loss. It is usually suitable for field termination using a mechanical or fusion splicer. Characterized by having an optical fiber connector on one end and a bare fiber end on the other, they are primarily used to connect optical transceivers or other optical.