ACCESS POINTS AND WIRELESS LAN CONTROLLERS EXPLAINED

Checking Access Points on Switches

Checking Access Points on Switches

Here are some basic steps that you can perform to troubleshoot the AP: Check the LED blinking pattern to identify possible errors. It provides direct access to the AP's configuration and status, allowing for quick diagnosis and resolution of issues. Access points must be discovered by a switch before they can become an active part of the network. You can use the status LED on your AP to determine some of the issues—for example, connectivity issues.

Read More
Several grounding points for communication tower feeder lines

Several grounding points for communication tower feeder lines

The fundamental objective of this document is to provide guidelines and practices for Ericsson site equipment grounding, with recommended methods that are essential to protect personnel, minimize component failure, and optimize performance by reducing electrical noise. #2 AWG minimum bare tinned solid copper ground wire may be used to bond air terminals to the tower. Because bonding and grounding systems within a building are intended to have one electrical potential, coordination between electrical and telecommunications bonding and grounding systems is essential during design and installation. It can enter via the feeder screens that are grounded at the top of the tower, via surge protective devices within or external to tower mounted electronics, via side flashing to exposed connection points and other electrical mechanisms.

Read More
How many network points can the server rack hold

How many network points can the server rack hold

Most racks are sold in the 42U form, which means a single rack can hold forty-two (42) 1U devices, or any combination of 1U, 2U, 3U or other rack unit heights that add up to 42 or less. Today, server racks are available in a wide range of sizes, each with different pros and cons. The main industry standard is the 19-inch rack, meaning the mounting rails are 482. It provides a secure and organized environment for servers, UPS systems, switches and other IT devices. Below is a comprehensive, fully detailed guide covering all standard server rack sizes, form factors, height considerations, depth classifications, and best-practice configuration approaches for professional environments. A rack space calculator is a specialized tool designed to help data center professionals, IT administrators, and network engineers determine the optimal placement and space requirements for equipment in server racks.

Read More
Fiber optic cable branching to multiple points

Fiber optic cable branching to multiple points

This tutorial review of fiber-optic branching devices covers example uses of branching devices, device types, device-performance characteristics, examples of current technology, and system-design methodology. A branching method for multi-fiber fiberoptic cables which comprises stripping off the jacket of a multi-fiber cable at the branching point, stripping the kevlar from the cable slightly beyond the branching point, folding back the kevlar over the jacket and holding the kevlar in place with heat. From the earliest stages of a new subsea cable project, understanding the pros and cons of utilising branching units or a festoon system is vital from a system design and cable security point of view. The discussion is limited to passive single- and multimode devices fabricated from optical.

Read More
Core issue Communication failure with access switch

Core issue Communication failure with access switch

Troubleshoot the connectivity issues of a switch by diagnosing the wired network. 0 trunk port enabled for vlan 103 able to ping access switch Access switch management vlan 192. We have a Huawei Core switch and a Dlink plug and play switch before the new Huawei Access switch was deployed. Network switches can experience various operational issues that disrupt network connectivity. These failures range from simple connection problems to complex configuration issues. Moving Firewall, no big issue and we connected it up to the 9000 and it reconncted with the other FIrewall and they connect to eatcher, we move the active firewalls from the firewall connected to the N5K switch to the firewall connected N9K switch.

Read More

Get In Touch

Connect With Us

📱

Spain Office (HQ)

+34 936 214 587

🇪🇺

EU Technical Center

+49 89 452 38 217

📍

Headquarters (Spain)

Calle de la Tecnología 47, 08840 Viladecans, Barcelona, Spain